Thermostatic Mixing Valve

Part Ref: EU-9201EFE


Model 9201EFE AXION® Emergency Tempering Valve thermostatically mixes hot and cold water to provide a safe fluid supply for a single emergency eye/face wash, with a flow rate of 12 gpm (38.8 L).

Category:

   

Description

Model 9201EFE Emergency Valve (patent pending) thermostatically mixes hot and cold water to provide a safe fluid supply for emergency eyewash equipment. Additionally, to ensure a fail-safe water supply for emergency eyewash stations, a series of cold water by-pass valves open in the event of hot water pressure loss. (No gauges supplied – ASSE 1071 standard recommends gauges be placed 5 to 8 feet (1.52 to 2.44 m) downstream for the most accurate temperature measurement.)

  • A flow rate of 1 to 12 gpm (3.8 to 45.4 L) for better temperature control across the operating range
  • AXION’s superior design and technology provide a complete safety solution for increased victim comfort.
  • Lowest internal pressure drop for this class of valve (advantage where supply pressure is low)
  • Wax based thermostat technology for fast response time with proven highly reliable temperature control
  • Highest Cold Water Bypass flow rate in the industry (83% of rated tepid flow rate)
  • Modular brass design with internal check stops
  • Over-sized valve seats resist failures caused by foreign matter
  • A new and efficient shuttle design eliminates valve sticking
  • A custom funnel design improves temperature control at low flow rates
  • Outlet temperature is factory set to 85® F (29® C).
  • Tempered water: High temperature limit is factory set to 90® F (32® C).
  • Cold water by-pass valves are closed during normal operation, regardless of flow rate.

Technical Details

Model 9201EFE (patent pending) is a thermostatic mixing valve that mixes hot and cold water to supply tempered water of up to 12 gpm (45.4 L) for emergency eyewash fixtures. Unit employs a paraffin filled thermostatic mixing element. Lowest internal pressure drop where supply pressure is low, and a high Cold Water Bypass flow rate of 10 gpm (37.8 L). The modular brass design with a one piece casting uses internal check stops, over-sized valve seats, a shuttle design that eliminates valve binding, and a funnel design to improve temperature control with better mixing at low flow rates. Lime and calcium resistant components are used throughout. The outlet temperature factory setting is 85® F (29® C). Maximum operating pressure: 125 psi (8.62 Bar). Temperature adjustment range 60 – 90® F (16 – 35® C). Min/max inlet hot water temperature: 120®/180® F (49®/82® C), with recommended inlet temperature: 140® F (60® C). Min/max inlet cold water temperature: 40®/70® (4.4®/21.1® C). Inlet 1/2″ NPT(F). Outlet 3/4″ NPT(F).